<> .p-pageWrapper .p-navSticky { top: 40px !important; } @media (max-width: 900px) { .p-pageWrapper .p-navSticky { top: 0 !important; } } .uix_mainTabBar {top: 115px !important;} .uix_stickyBodyElement:not(.offCanvasMenu) { top: 135px !important; min-height: calc(100vh - 135px) !important; } .uix_sidebarInner .uix_sidebar--scroller {margin-top: 135px;} .uix_sidebarInner {margin-top: -135px;} .p-body-sideNavInner .uix_sidebar--scroller {margin-top: 135px;} .p-body-sideNavInner {margin-top: -135px;} .uix_stickyCategoryStrips {top: 135px !important;} #XF .u-anchorTarget { height: 135px; margin-top: -135px; } @media(max-width: 900px) { .uix_mainTabBar {top: 75pxpx !important;} .uix_stickyBodyElement:not(.offCanvasMenu) { top: 95px !important; min-height: calc(100vh - 95px) !important; } .uix_sidebarInner .uix_sidebar--scroller {margin-top: 95px;} .uix_sidebarInner {margin-top: -95px;} .p-body-sideNavInner .uix_sidebar--scroller {margin-top: 95px;} .p-body-sideNavInner {margin-top: -95px;} .uix_stickyCategoryStrips {top: 95px !important;} #XF .u-anchorTarget { height: 95px; margin-top: -95px; } } @media (max-width: $uix_sidebarBreakpoint) { .p-sectionLinks {display: none;} .uix_mainTabBar {top: 115px !important;} .uix_stickyBodyElement:not(.offCanvasMenu) { top: 135px !important; min-height: calc(100vh - 135px) !important; } .uix_sidebarInner .uix_sidebar--scroller {margin-top: 135px;} .uix_sidebarInner {margin-top: -135px;} .p-body-sideNavInner .uix_sidebar--scroller {margin-top: 135px;} .p-body-sideNavInner {margin-top: -135px;} .uix_stickyCategoryStrips {top: 135px !important;} #XF .u-anchorTarget { height: 135px; margin-top: -135px; } @media(max-width: 900px) { .uix_mainTabBar {top: 75px !important;} .uix_stickyBodyElement:not(.offCanvasMenu) { top: 95px !important; min-height: calc(100vh - 95px) !important; } .uix_sidebarInner .uix_sidebar--scroller {margin-top: 95px;} .uix_sidebarInner {margin-top: -95px;} .p-body-sideNavInner .uix_sidebar--scroller {margin-top: 95px;} .p-body-sideNavInner {margin-top: -95px;} .uix_stickyCategoryStrips {top: 95px !important;} #XF .u-anchorTarget { height: 95px; margin-top: -95px; } } } .uix_sidebarNav .uix_sidebar--scroller {max-height: calc(100vh - 95px);}

New guy with indoor boiler questions.

  • Active since 1995Hearth.com is THE place on the internet for free information and advice about wood stovespellet stoves and other energy saving equipment.

    We strive to provide opinionsarticlesdiscussions and history related to Hearth Products and in a more general senseenergy issues.

    We promote the EFFICIENTRESPONSIBLECLEAN and SAFE use of all fuelswhether renewable or fossil.
You are using an out of date browser. It may not display this or other websites correctly.
You should upgrade or use an alternative browser.

2broke2ride

Burning Hunk
Hearth Supporter
Dec 232014
224
Townsend MA
Hi therekinda new here looking for advice.
I am looking to install a used indoor wood boiler in conjunction with my oil boiler.
I have researched up and down but need someone to dumb it down for me lol as well as maybe provide some links to parts. AlsoI have not yet purchased a used boiler yet so any advice there's appreciated. I need this to be as inexpensive as possible while still being safe.
I understand the boiler needs to plumb in with my current boiler in parallel using "closely spaced tees" I assume that means the out and return from the wood boiler plumb into the main loop basically side by side????
I also understand i need a "heat dump" that can dissipate the full btu of the boiler in case of power outage or radiators not calling for heat. What would this look like? What parts are needed here?
Diagrams of how to plumb this would be super helpful. I am no dummy and I'm not scared to do thisjust want to make sure I do it right.
Thanks.
 
Subscribed.

Once you determine what manufacturethe best thing is to follow the installation instructions. I’m sure you have also come across the DIY boiler and installation information in your searching.

Here is a thread specifically on your thermal dump question.


There is also a lot of free manualsand online picturesfrom manufacturers on the plumbing setup regarding power failuresmost include a NO valve (opens on failure/power failure) along with a prescribed loop length.
 
I'd highly recommend installing storage...and that takes care of your heat dump issue too.
 
My backup oil boiler is hooked up with close spaced tee's after my heat ex changer from storage. Storage is water. Underground lineshouse and backup boiler are on glycol
 
I downloaded an owners manual for a Kerr 101T that I am considering and it instructs to plumb in series???? Is that appropriate? Everything I've been reading says it should be plumbed in parallel.
Alsomy system is a monoflow system with one main loopis there a reason that big loop and all the baseboards wouldn't function as a "heat dump"
Sorry for all the questionsjust trying to understand this.
 
Storage with boiler protection is a must with this boiler.Plus dry wood 14/15 % moisture content. I had the forced air version of this boiler many years ago like 50 years !
Plumbing in series allows you to use the oil boilers controls but a t a big hit in wasted BTU's can be as high as 350,000 per day .
 
  • Like
Reactions: salecker
Are you joking??? Or does it really do that? SorryI'm super new to this boiler stuffI've had wood stoves and wood furnaces for 40 years but never a boiler so some things go over my head lol.
 
  • Like
Reactions: hobbyheater
Are you joking??? Or does it really do that? SorryI'm super new to this boiler stuffI've had wood stoves and wood furnaces for 40 years but never a boiler so some things go over my head
Several of the boilers from the 70's did that and the Kerr Titan did !

The gasifcation boilers of today require storage or a dump zone.
The Kerr Titan still may be available new from from Kerr Contols Turo Novia Scotia !
 
You need storageeven though the boiler will shut downit still smouldersyou need that heat somewhere to go or else your in big trouble. It still can be a problem once the storage is hot and you have no load on the systemdepends how full you loaded the boiler. You need to design to heat your space and load the tanks to temp in about an 8 hr burn works well.
 
On a normal winter day -20C around 4 below F with my 1000 gallons of storage i fire from 5 PM to 11 PM when i go to bed i shut the boiler off.
According to the gauges the highest temp i have achieved at a regular burn is 186Fso there is still some room for BTU's
 
  • Like
Reactions: all night moe
On a normal winter day -20C around 4 below F with my 1000 gallons of storage i fire from 5 PM to 11 PM when i go to bed i shut the boiler off.
According to the gauges the highest temp i have achieved at a regular burn is 186Fso there is still some room for BTU's
Storage is nice to have but it is not cheap to do.
 
I think thermal storage is the best way to gobut for different reasons some may decide or not be able to put it in. There are a few units that are advertised to work without thermal storagesuch as Polar and Woodgunand they both make indoor units. But the high efficient units that can get by without thermal storage are mostly newer modelsI believeso you may have a difficult time finding a suitableefficient unit that will work well without storage. If you don't care about the efficiencythen you will have an easier time finding a unit. PersonallyI like the thermal storage from a couple of standpointsefficiency being onebut another is safety. With my Switzermy burns take in the 2 hour time frameand usually I do those at a time when I am at home. Outside thatthere is no fire in the unit.
 
Storage is nice to have but it is not cheap to do.
All mine cost me was my time and spray foam
Tanks were freehad salvage steel for the mounts. I made a steel frame that held both tanks upright and together. Spray foamed then and slid the tank assembly into the corner of the boiler building.
Every time i go to the junk yard i see numerous tanks for storage. I took 5 pressure tanks to the dump here before that started charging tipping fees
 
The Polars will work good without storage but they get even better with it. Mine is the G2+ and I have 1500 gallon of nonpressurized storagemy folks have a G3 with no storagemy burns are still cleaner and even accounting for load differences mine uses less wood per day than theirs. I run mine like a conventional i guess you would sayor as if it didn't have storagethe boiler still controls itself and my homemade control board runs the circsit also has an overheat protection built in so that if the boiler goes above 187 the boiler to storage circ kicks on to dump that heat to the storagehave never had any issues with getting way to hoteven in a power failure situation because the air manifolds close with no power and the draft fan dies. It will once in a while shoot a bit high to where the protect circuit comes in if the storage is satisfied before the boiler gets therebut that protect circuit kicks in and cools the boiler down and only raises storage maybe 2 degrees above setpoint so not a big deal.
 
  • Like
Reactions: salecker
Storage is nice to have but it is not cheap to do.
I missed out on an Eko 60 setup with 1000 gallons of pressurized storage a while backbut it was just not the right timing (I had just bought an Eko 40and was still learning the basics of setting up a system). Talking to the guyhe was telling me how expensive the tanks were (pressurized storage)and how I wouldn't find one for under $10K used (his was a bare tank as well--no insulation)so I thought I was screwed on the storage aspect....

A couple of weeks laterI happened upon a 1040 galloncertified tank for $900unused from an industrial heating project that got cancelledabout an hour away from meso I picked that up and am working on it. The tank goes new for around $18K. I also just came across another tank local to me that's 2400 gallonsfor $600but the certs are questionable (mine was certified to 125psi @ 200F which covers both pressure and temp for my system quite readilythe 2400 gallon was something like 100psi @ 150Fand I didn't know how that affected higher temps at lower pressures..).

Certainly ways to do it *cheaper* (I still have money/work needed to be spent on setting the tank up and insulating it) but it takes some time searching for the deals and putting in the work on something that's not just 'turn-key'.

I get what *YOU* area sayingand you're absolutely rightbut if OP is willing to put the time into to searching for solutions and can make it work (I'm semi-handy and can weld)storage can absolutely be achieved for a reasonable price and quickly pay for itself.
 
storage doesnt have to be crazy expensive . while i only have 500 gallons it works well for my 1700 sq ft home. Found a used propane tank for $200 cleaned it ,then trailered it to the Econoburn factory (my boiler manuf.) and had the necessary ports welded on and 6" insulated for $600. This was in 2014 and in todays inflationary world prices would certainly be higher but not 10K!
 
my storage tank is an anhydrous ammonia tank that got decommissioned because one of the brackets that mount to the axle cracked off for some reasonI bought it for 150 bucksI installed my own plumbing fitting and pipesits 1500 gallons
 
The tanks i used were old propane tanksi still have a couple that may get used for my new shop if i go that route.
There is an Econoburn 300 sitting plugged solid and unused for the last 5 years i am hoping to get close to the free price.
 
  • Like